GB12666.6 Fire Resistant Cables PVC Insulation PVC Sheath Electrical Wire
Place of Origin | Jiangsu China |
---|---|
Brand Name | Jiangnan |
Certification | CE, RoHS, CCC,ISO |
Model Number | NH-VV |
Minimum Order Quantity | 500 Meters |
Price | $0.3/meter |
Packaging Details | Customized logo(Min. order 5000 meters) Customized packaging(Min. order 5000 meters) Graphic customization(Min. order 5000 meters) |
Supply Ability | 50000meter/7days |

Contact me for free samples and coupons.
WhatsApp:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xModel Number | NH-VV | Application | Aerial And Duct |
---|---|---|---|
Conductor Type | Solid | Product Name | Copper Core PVC Insulation Wire |
Conductor Material | Fiber | Insulation Material | PE |
Insulation | PVC Insulation Cable | Rated Voltage | 300/500V 450/750V |
Standard | GB12666.6 | Color | Requirement |
Highlight | GB12666.6 Fire Resistant Cables,Fire Resistant Cables PVC Insulation,GB12666.6 fire resistant electrical wire |
This product is suitable for power frequency rated voltage 3.6/6kv ~ 26/35kv power transmission and distribution lines for power distribution.
1. Product use: This product is suitable for power lines with a rated voltage (U0/U) of 3.6/6 to 26/35KV for power transmission and distribution.
2. Product standard: GB12706-91 rated voltage 35KV and below copper core, aluminum core plastic insulated power cable.
3. Product use characteristics: (1) When the cable is laid under the condition that the ambient temperature is not lower than 0 ℃, it is not necessary to pre-heat. Cable laying heights are not restricted. (2) The long-term allowable operating temperature of the cable core shall not exceed the following regulations: 90°C for cables with a polyvinyl chloride sheath on the outer sheath; 80°C for cables with a polyethylene sheath on the outer sheath. (3) When the wire core is short-circuited (the longest duration is 5S), the temperature shall not exceed 250°C (4) The minimum bending radius when laying the cable is specified as follows: single-core cable: 20 (d+D) ± 5%; three-core cable: 15 (d+D)±5%. Where: D is the actual outer diameter of the cable, d is the actual outer diameter of the conductor
A: We are factory.
Q: How long is your delivery time?
A: Generally it is 5-10 days if the goods are in stock. or it is 15-20 days if the goods are not in stock, it is according to
quantity.
Q: Do you provide samples ? is it free or extra ?
A: Yes, we could offer the sample for free charge but do not pay the cost of freight.
Q: What is your terms of payment ?
A: 30% T/T in advance, balance before shipment